Az elektromágneses szennyezettség korróziós hatásai épített környezetünk acél és vasbeton szerkezeteire
Corrosive effects of electromagnetic pollution on the steel and reinforced concrete structures from the complex built-up media
Kulcsszavak:
corrosion, stray currents, electromagnetic pollution, built-up media, artifacts, /, korrózió, kóboráramok, elektromágneses szennyezés, beépített környezet, műtárgyakAbsztrakt
The corrosion effects of electromagnetic pollution and stray currents on steel and reinforced concrete structures in our built-up media have been investigated. The investigations show that direct and alternating stray currents cause significant corrosion damage in steel and reinforced concrete structures in our built-up media. Corrosion damage caused by the synergistic effects of complex DC and AC stray currents is particularly dangerous.
Összefoglaló
Az elektromágneses szennyezettség, kóboráramok által okozott, korróziós hatásai az épített környeze-tünk acél és vasbeton szerkezeteire lettek megvizsgálva. A vizsgálatokból megállapítható, hogy épített környezetünk acél és vasbeton szerkezeteiben az egyen és váltakozó áramú kóboráramok számottevő korróziós rongálódásokat okoznak. Különösen veszélyesek az összetett (egyen és váltakozó áramú) kóboráramok szinergiás hatásai által okozott korróziós rongálódások.
Hivatkozások
[1] Chen, Y. (1995), A Fuzzy Decision System for Fault Classification Under High Levels of Uncertainty, Transactions of the ASME -Journal of Dynamic Systems, Measurement, and Control, 117, pp.108-115.
[2] I. Lingvay, M. Gabor, C. Lingvay, Degradation by corrosion of steel rebars from reinforced concrete structures. 1 Studies regarding the corrosion of the Bucharest metro’s structures of concrete steel, Rev. Chim. (Bucureşti) 57, nr. 2, 2006. pp. 180-183
[3] I. Lingvay, A. M. Bors, D. Lingvay, l. Radermacher, V. Neagu, Electromagnetic Pollution of the Environment and its Effects on the Materials from the Built up Media, REV.CHIM.(Bucharest), vol. 69 (12), 2018. pp. 3593-3599
[4] I. Lingvay, C. Lingvay, C. Homan, O. Ciogescu, Degradation by corrosion of steel rebars from reinforced concrete structures. 5. Contributions to the Study of Corrosion of Concrete Steel Sustaining Elements from the Systems Involved in Energy Transportation and Distribution, Rev. Chim. (Bucureşti), 57, nr. 12. 2006, pp.1279-1282.
[5] I. Lingvay, S. Gombos, C. Lingvay, J. Kovács, C.D. Voiniţchi, Degradation by corrosion of steel rebars from reinforced concrete structures. 4. The pH and chemical composition modifications of concrete caused by stray currents, Rev. Chim. ( Bucureşti) 57, nr. 5, 2006, pp. 498-500
[6] I. Lingvay, M. Gabor, C.D. Voiniţchi, C. Lingvay, Degradation by corrosion of steel rebars from reinforced concrete structures. 3. Contributions to Study of Physico-Mechanical Degradation of Reinforced Concrete due to Stray Currents, Rev. Chim. (Bucureşti) 57, nr. 4, 2006, pp. 378-382
[7] I. Lingvay, Degradation by corrosion of steel rebars from reinforced concrete structures. 2. Contributions to study of degradation mechanism of reinforced concrete structures situated in natural electrolytic media, Rev. Chim. (Bucureşti) 57, nr.3, 2006 pp. 261-265
[8] Puklus Z., Lingvay J.,, Hodossy L., A kóboráramok és hatásainak vizsgálata a millenniumi földalatti vasút környezetében, Korróziós figyelő 45, 2, 2005 pp. 43-48.
[9] Neville, A.M., Properties of Concrete, Pitman Publishing Ltd.1975, p.370.
[10] R. Piltner, Paulo J.M. Monteiro, Stress analysis of expansive reactions in concrete, Cement and Concrete Research 30 (2000) 843-848
[11] I. Lingvay, G. Rus, F. Stoian and C. Lingvay, Corrosion Study of OL37 Carbon Steel in the Presence of Both Aspergillum Niger Fungi and AC Stray Currents, UPB Sci. Bull, Series B, Vol. 63, No. 3, 2001, pp. 263-270.
[12] I. Lingvay, Contributions to Study and Control of Accelerated Corrosion due to AC Stray Currents, 12th Romanian International Conference on Chemistry and Chemical Engineering" vol. Quality Control and Analytical Chemistry - Corrosion and Electrochemistry, Bucharest, september 13-15, 2001, pp. 342-355.
[13] Lingvay J., Lingvay C.,, A háromfázisú energetikai rendszer földeléseinek korróziós károsodásai, Korróziós figyelő, 46, 1, 2007. pp. 8-12
[14] Lingvay, I., Homan, C., Lingvay, C., Corrosion study of zinc covered steel of ground plates from the three-phase power system , Rev. Chim. (Bucureşti), 58, nr. 11, 2007. pp. 1051-1054
[15] Lingvay J, Szatmári I, Lingvay M., Tudosie L., Az erõsáramú kábelek öregedése. Esettanulmány – 5 éves megfigyelések eredményei: Korróziós figyelő, Vol. LIII (3) 2013. pp. 71 – 80
[16] Lingvay J., Hozzájárulás a csőrendszerek váltakozóáram okozta korróziójának vizsgálatához és megelőzéséhez, Korróziós figyelő 44, 2, 2004 pp. 49-56.